Downloading physical disk firmware – Dell PowerVault MD3200i User Manual

Page 208

Advertising
background image

206

Management: Firmware Downloads

NOTE:

The Details pane shows the details of only one storage array at a time.

If you select more than one storage array in the Storage array pane, the

details of the storage arrays are not shown in the Details pane.

9 Click NVSRAM in the Download area.

NOTE:

If you select a storage array that cannot be upgraded, the NVSRAM

button is disabled.

The Download NVSRAM dialog is displayed. The current firmware

version and the NVSRAM version of the selected storage arrays is

displayed.

NOTE:

If you select the storage arrays with different RAID controller module

types that cannot be updated with the same NVSRAM file and click NVSRAM,

the Incompatible RAID Controller Modules dialog is displayed. Click OK to

close the dialog and select the storage arrays with similar RAID controller

module types.

10 To locate the directory in which the NVSRAM file to download resides,

click

Browse in the Select file area.

The

Select File dialog is displayed.

11 Select the file to download and click OK.

Any attributes of the NVSRAM file are displayed in the NVSRAM file

information area. The attributes indicate the version of the NVSRAM file.

12 Click OK.

The

Confirm Download dialog is displayed.

13 Click Yes.

The download starts and a progress indicator is displayed in the Status

column of the Upgrade RAID Controller Module Firmware window.

Downloading Physical Disk Firmware

CAUTION:

When updating physical disk firmware, you must stop all I/O activity to

the array to prevent data loss.

The physical disk firmware controls various features of the physical disk. The

disk array controller (DAC) uses this type of firmware. Physical disk firmware

stores information about the system configuration on an area of the physical

book.book Page 206 Tuesday, June 18, 2013 3:15 PM

Advertising
This manual is related to the following products: