Dell PowerVault DP100 User Manual

Page 8

Advertising
background image

configurations.

Keyboard controller failure

Faulty keyboard controller
(faulty system board).

See

Getting Help

.

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Loose or improperly
connected keyboard cable;
faulty keyboard; faulty
keyboard controller.

Ensure that the keyboard is
properly connected. If the
problem persists, replace the
keyboard. If the problem
persists, see

Getting Help

.

Keyboard fuse has failed.

Keyboard fuse has failed.

Replace the keyboard.

Manufacturing mode detected

System is incorrectly
configured.

Install the NVRAM_CLR jumper
and reboot the system. See

System Board Jumpers

for

jumper location.

Memory address line failure

at address, read value

expecting value

Memory double word logic

failure at address, read

value expecting value

Memory odd/even logic

failure at address, read

value expecting value

Memory write/read failure

at address, read value

expecting value

 

Faulty or improperly installed
memory modules, or faulty
system board.

Ensure that all memory
modules are properly installed.
See

Troubleshooting System

Memory

. If the problem

persists, see

Getting Help

.

Memory tests terminated by
keystroke

The spacebar was pressed
during POST to terminate the
memory test.

Do not press spacebar during
memory test.

 

More than one RAC detected,
system halted

 

Verify that the RAC is installed
in the proper PCI expansion
slot (SLOT_5). If a RAC is
installed in any other slot,
remove it.

No boot device available

Faulty or missing diskette
drive, optical drive, or hard
drive.

Check the Integrated Devices
configuration settings in the
System Setup program. See

Using the System Setup
Program

. Ensure that either

SATA Controller, Diskette
Controller
, or IDE Controller
is enabled. If the system is
booting from a SCSI controller,
ensure that the controller is
properly connected. If the
problem persists, replace the
drive. See

Hard Drives

.

No boot sector on hard-disk
drive

An operating system is not on
the hard drive.

Check the hard-drive
configuration settings in the
System Setup program. See

Using the System Setup
Program

.

No timer tick interrupt

Faulty system board.

See

Getting Help

.

Not a boot diskette

Not a bootable diskette.

Use a bootable diskette.

PCI BIOS failed to install

Loose cables to expansion
card(s); faulty or improperly
installed expansion card.

Ensure that all appropriate
cables are securely connected
to the expansion cards. See

Troubleshooting Expansion
Cards

.

PCIe Degraded Link Width

Error:

Embedded

Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed
PCIe card.

Reseat the PCIe cards. See

Expansion Cards

. If the

problem persists, see

Getting

Help

.

PCIe Degraded Link Width

Error: Slot n

Expected Link Width is n

Actual Link Width is n

 

Faulty or improperly installed
PCIe card in the specified slot
number.

Reseat the PCIe card in the
specified slot number. See

Expansion Cards

. If the

problem persists, see

Getting

Help

.

PCIe Training Error:
Embedded
Bus#nn/Dev#nn/Funcn

Faulty or improperly installed
PCIe card.

Reseat the PCIe cards. See

Expansion Cards

. If the

problem persists, see

Getting

Help

.

PCIe Training Error: Slot n

Faulty or improperly installed
PCIe card in the specified slot

Reseat the PCIe card in the
specified slot number. See

Expansion Cards

. If the

Advertising