Troubleshooting a scsi tape drive – Dell PowerEdge R300 User Manual

Page 143

Advertising
background image

Troubleshooting Your System

143

Troubleshooting a SCSI Tape Drive

Problem

Defective tape drive

Defective tape cartridge

Missing or corrupted tape-backup software or tape drive device driver

Defective SCSI controller

Action

1 Remove the tape cartridge you were using when the problem occurred, and

replace it with a tape cartridge that you know works.

2 Ensure that the SCSI device drivers for the tape drive are installed and are

configured correctly. See "Optical Drive" on page 80.

3 Reinstall the tape-backup software as instructed in the tape-backup

software documentation.

4 Ensure that the tape drive’s interface/DC power cable is connected to the

tape drive and SCSI controller card.

5 Verify that the tape drive is configured for a unique SCSI ID number and

that the tape drive is terminated or not terminated, based on the interface
cable used to connect the drive.

See the documentation for the tape drive for instructions on selecting the
SCSI ID number and enabling or disabling termination.

6 Run the appropriate online diagnostics tests. See "Using Dell PowerEdge

Diagnostics" on page 153.

7 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

8 Open the system. See "Opening and Closing the System" on page 70.