Dell PowerEdge R300 User Manual

Page 29

Advertising
background image

About Your System

29

E1811

HDD ## Rbld

Abrt

The specified hard drive has
experienced a rebuild abort.

See "Troubleshooting a
Hard Drive" on page 144.
If the problem persists,
see your RAID
documentation.

E1812

HDD ##

Removed

The specified hard drive has
been removed from the
system.

Information only.

E1913

CPU &

Firmware

Mismatch

The BMC firmware does not
support the CPU.

Update to the latest BMC
firmware. See the BMC
User’s Guide for more
information on setup and
use of BMC.

E1A12

PCI Rsr

Config

One or all of the PCIe risers
is configured incorrectly,
preventing the system from
powering on.

Reinstall the missing riser
card(s).

E1A12

PCI Rsr

Missing

One or all of the PCIe risers
is missing, preventing the
system from powering on.

Check that all
connections are secure
and correctly positioned.

E1A14

SAS Cable A

SAS cable A is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 167.

E1A15

SAS Cable B

SAS cable B is missing or
bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 167.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

book.book Page 29 Sunday, June 21, 2009 5:16 PM