Troubleshooting a hot-plug hard drive – Dell PowerEdge R300 User Manual

Page 145

Advertising
background image

Troubleshooting Your System

145

See the documentation supplied with the host adapter for information
about the configuration utility.

b

Ensure that the hard drive has been configured correctly for the RAID.

c

Exit the configuration utility and allow the system to boot to the
operating system.

4 Ensure that the required device drivers for your SAS controller card or SAS

RAID controller are installed and are configured correctly. See the
operating system documentation for more information.

5 Verify that the controller is enabled and the drives appear in the System

Setup program. See "Entering the System Setup Program" on page 47.

6 Check the cable connections inside the system:

a

Turn off the system, including any attached peripherals, and
disconnect the system from the electrical outlet.

b

Open the system. See "Opening and Closing the System" on page 70.

c

Verify that the cable connections between the hard drive(s) and the
drive controller are correct, whether the connections are to the SATA
connectors on the system board, a SAS expansion card, or a SAS RAID
controller. See "Hard Drives" on page 74.

d

Verify that the SAS or SATA cables are securely seated in their
connectors.

e

Close the system. See "Opening and Closing the System" on page 70.

f

Reconnect the system to the electrical outlet, and turn on the system
and attached peripherals.

If the problem persists, see "Getting Help" on page 167.

Troubleshooting a Hot-plug Hard Drive

Problem

Device driver error.

One or more hard drives not recognized by the system.

book.book Page 145 Sunday, June 21, 2009 5:16 PM

Advertising