Dell PowerEdge R300 User Manual

Page 27

Advertising
background image

About Your System

27

E161C

PS # Input

Lost

Power source for specified
power supply is unavailable,
or out of acceptable range.

Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 135.

E1624

PS Redundancy

The power supply subsystem
is no longer redundant. If
the last supply fails, the
system will go down.

See "Troubleshooting
Power Supplies" on
page 135.

E1710

I/O Channel

Chk

The system BIOS has
reported an I/O channel
check.

See "Getting Help" on
page 167.

E1711

PCI PERR B##

D## F##

The system BIOS has
reported a PCI parity error
on a component that resides
in PCI configuration space
at bus ##, device ##,
function ##.

Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.

PCI PERR Slot

#

The system BIOS has
reported a PCI parity error
on a component that resides
in the specified PCIe slot.

Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

book.book Page 27 Sunday, June 21, 2009 5:16 PM