Dell PowerEdge R300 User Manual

Page 23

Advertising
background image

About Your System

23

Table 1-6.

LCD Status Messages

Code

Text

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character string that
can be defined by the user in
the System Setup program.

The SYSTEM NAME
displays under the following
conditions:

• The system is powered on.

• The power is off and

active errors are displayed.

This message is for
information only.

You can change the
system ID and name in
the System Setup
program. See "Entering
the System Setup
Program" on page 47.

E1000

FAILSAFE,

Call Support

Check the system event log
for critical failure events.

See "Getting Help" on
page 167.

E1114

Temp Ambient

Ambient system
temperature is out of
acceptable range.

See "Troubleshooting
System Cooling
Problems" on page 136.

E1115

Temp Planar

Planar system temperature
is out of acceptable range.

See "Troubleshooting
System Cooling
Problems" on page 136.

E1118

CPU Temp

Interface

The BMC is unable to
determine the CPU(s)
temperature status.
Consequently, the BMC
increases the CPU fan speed
to maximum
as a precautionary measure.

Turn off power to the
system and restart the
system. See "Getting
Help" on page 167.

E1210

CMOS Batt

CMOS battery is missing, or
the voltage is out of
acceptable range.

See "Troubleshooting the
System Battery" on
page 134.

book.book Page 23 Sunday, June 21, 2009 5:16 PM