Maintenance --filesystem [--repair_now – Dell PowerVault DR2000v User Manual

Page 109

Advertising
background image

Result

Filesystem checker is not running.

maintenance --filesystem [--repair_history [verbose]]

Description

Displays the filesystem checker history for a DR Series system.

Syntax

maintenance --filesystem --repair_history

Result

0 : Filesystem check time : Mon Jun 11 14:37:43 2012

Dry run finished at : Mon Jun 11 14:38:03 2012

Release version : 32309

Data verification : not enabled

Result: No inconsistencies discovered

1 : Filesystem check time : Tue Jun 12 12:35:33 2012

Dry run finished at : Tue Jun 12 12:36:21 2012

Release version : 32309

Data verification : not enabled

Result: No inconsistencies discovered

2 : Filesystem check time : Fri Jun 15 10:09:14 2012

Dry run finished at : Fri Jun 15 10:11:12 2012

Release version : 32309

Data verification : not enabled

Result: No inconsistencies discovered

3 : Filesystem check time : Thu Jun 21 11:47:40 2012

Dry run finished at : Thu Jun 21 11:49:22 2012

Release version : 32309

Data verification : not enabled

Result: No inconsistencies discovered

maintenance --filesystem [--scan_restart [verify_data | verify_rda_metadata |

verify_metadata]]

Description

Restarts file system checker to generate updated report.

NOTE: Argument verify_data validates data with pre-built checksum. Argument verify_rda_metadata
scans only OST and RDA containers. Argument verify_metadata scans only the namespace for all
containers.

Syntax

maintenance --filesystem --scan_restart [verify_data| verify_rda_metadata |

verify_metadata]

Result

Successfully restarted filesystem scan.

maintenance --filesystem [--repair_now]

Description

Repairs any filesystem issues in a DR Series system based on the repair report findings.

109

Advertising