Class of Service Configuration

Early Detect Drop Profile Configuration

96

10.3.4 Weight Parameters

NOTE: Queue 3, Queue 2 and Queue 1 require a Weight parameter range between 0

and 1000. If you enter an invalid weight parameter, INVALID INPUT will appear
at the bottom of the screen.

If WFQ is set as the scheduling method, a weigh need to be assigned to each queue. The queue is
proportional to how much bandwidth that queue will receive. The weight value can be of any range
between 0-1000. Type the appropriate number to change the queue weight; 6 for Queue 3, 12 for Queue 2
or 18 for Queue 1. Type in the new setting. Press

Enter to confirm setting.

10.3.5 Early Detect Drop Profiles

Early Detect is a congestion avoidance mechanism that allows you to drop packets based on a specific
profile. The drop can be selectively applied to packets with a specific PCP value or a priority. Doing so
allows you to drop packets before a specific queue is full.

Every Queue has two drop profiles associated to it. They use can configure those drop profile and
associate to a specific class of service. The customer has the ability to enable or disable each ED Drop
Profile independently. Type the appropriate number for the schedule scheme you wish to modify; 7 or 8 for
Queue 3, 13 or 14 for Queue 2, and 19 or 20 for Queue 1. Use the

Space Bar to select Enabled or

Disabled. Press

Enter to confirm setting.

10.4 Early Detect Drop Profile Configuration

You can enable and disable each drop profile, as well as set the MIN, MAX, and MID values for each
queue. From the Class of Service Configuration screen, type either 4 or 9 and press

Enter. The ED Drop

Profile Configuration screen (Figure 10-7) opens.

1.

Use

Ctrl+T to select Drop Profile A or Profile B.

2.

Type

1, 5 or 9 to set the minimum threshold percentage for the appropriate Drop Profile, use

Backspace to remove the current setting, type in the desired setting, and press Enter to set.

3.

Type

2, 6 or 10 to set the maximum threshold percentage for the appropriate Drop Profile, use

Backspace to remove the current setting, type in the desired setting, and press Enter to set.

4.

Type

3, 7 or 11 to set the Mid threshold percentage for the appropriate Drop Profile, use

Backspace to remove the current setting, type in the desired setting, and press Enter to set.