9145E NID Software User’s Manual

System Configuration

IP/SNMP Agent Configuration

16

3.

Select the Notification Type for this SNMP host. Selections are: V1-Trap, V2c-Trap, V2c-Inform,
V3-Trap, and V3-Inform.

NOTE: Each Notification Type has a different configuration procedure. Follow the

specific procedure for the Notification Type selected.

If V1-Trap or V2c-Trap was selected (Figure 3-9):

a. Enter the Community Name.

b. Press Enter.

c. Press Esc to return to the Trap Table menu (Figure 3-7).

Figure 3-9 V1-Trap or V2c-Trap Notification Type Parameter

If V2c-Inform was selected (Figure 3-10):

a. Enter the Community Name.

b. Accept or revise the Retries parameter (default is 3).

c. Accept or revise the Timeout in Seconds parameter (default is 5).

d. Press Enter and then press Esc to return to the Trap Table menu (Figure 3-7).