9145E NID Software User’s Manual

Software Upgrade

Swap Bank After Download and Reset

74

Figure 8-1 Software Upgrade Screen

8.3 Swap Bank After Download and Reset

Option 3 allows you to select automatically swapping banks on reset after a successful download. Select
Yes for automatically swap banks. Select No to have downloaded software remain in the inactive bank.
This option does not generate a reset.

Type

3 and press Enter. Press the Space Bar to cycle between Yes and No.

NOTE: Users will be disconnected when the 9145E is reset.

The flag must be set before the download of the new software while Swap Bank after Download and reset
is set. After downloading software, the message line will read Loads xx.xx on Next Reset.

Canoga Perki ns Corp. Ethernet Network Interface Devi ce 12-SEP-2008
Model 9145E-101-2-0 V02.10 F121 02: 59: 35
---------------------------------------SOFTWARE UP GRADE---------------------------------

Time Since Last Restart

06:29:05


Version

File

Name

Fi le

Size


Active

Firmware

2.0

9145E-A10-02-00.ZIP

2225458

Inactive Firmware

2.1

9145E-A10-02-01.ZIP

2235776

Bootcode

2.1

9145E-B00-02-10.BIN

337566


1) Software Reset

Reset

2) Swap Bank & Reset

Swap

3) Swap Bank after
download

and

reset

Yes


4) Get New File wit h TFTP

Select [1-4]

:---------------------------------------------Messages---------------------------------------------

Extension Port Link Up

Advertising