Installing The Furnace

9

1

SHIPPING 

The furnace is shipped disassembled for ease in handling and moving into location where it is to be installed. 
(Refer to Table 2 for information on the items shipped with each furnace.) 

Table  2 

MODEL 

BRICK 

ELEMENTS 

DUCTING 

(See  Note  1) 

(See  Note  2) 

(See  Note  3) 

DLF30B 

28 boxes Whole Brick (3/Box) 

1 Box Return Air Filter Rack 

2 boxes Half Brick (6/Box) 

1 Box Supply Air Blower Plenum Assembly 

1  Hardware  Package  (See  Note  4) 

DLF40B 

37 boxes Whole Brick (3/Box) 

12 

1 Outdoor Temperature Sensor (See Note 5) 

2 boxes Half Brick (6/Box) 

NOTES:  1.  The  furnace  ships  in  two  sections  (brick  storage  cavity  and  base  assembly)  banded 

to  one  pallet. 

2.  Each  brick  box  weighs  approximately  72  lbs  each. 
3.  The  elements  are  shipped  inside  the  brick  storage  cabinet  of  the  furnace. 
4.  The  hardware  package  is  shipped  in  the  base  assembly  portion  of  the  furnace. 
5.  The  outdoor  temperature  sensor  is  shipped  in  the  supply  air  blower  plenum  assem­ 

bly  box. 

PLACEMENT 

The physical dimensions of the furnace along with the clearances required must be taken into consideration 
when choosing a location for the furnace.  The minimum area needed for the installation of a furnace is 100 
square feet.  The best installation location for the furnace is in an area it will be heating.  Although most of the 
heating requirements of the space will be satisfied by the heat delivered through the duct system, a small amount 
of the heating requirements will also be satisfied through static heat dissipating through the furnace's warm 
outside panels. In situations where the furnace will not be installed in the area it is intended to heat (i.e. garage), 
it is important to account for the heat lost through its panels by making proper adjustments in sizing of the 
furnace. 

In addition to the physical space requirements, the weight of the furnace must also be taken into consideration 
when selecting the installation surface.  A level concrete floor is the best surface on which to place the furnace, 
but most well supported surfaces are acceptable.  If in doubt about floor load capacity, consult a building con­ 
tractor or architect.  (See Figure 2 for furnace and ducting dimensions.) 