General information – Steffes DLF40B User Manual

Page 4

Advertising
background image

Automatic  Charge  Control 

Method of brick core charge regulation where a sensor monitors outdoor 
temperature to automatically adjust the brick core temperature setting in relation 
to the outdoor temperature. 

Brick  Core  Charge  Level 

The amount of heat that is stored in the heater’s brick core. 

Charge  Period 

Off­peak time in which the furnace is allowed to store heat in its brick core. 

Control  Panel 

Contains the toggle switches to adjust and display lights to indicate furnace 
operation.  Located on the lower front of the furnace on the electrical panel. 

Control  Period 

On­peak time in which the furnace is not allowed to store heat in its brick core. 

Heat  Call 

When room temperature falls below the room’s thermostat setting, the thermo­ 
stat signals the furnace to operate its blowers and deliver warm air into the 
space to raise the temperature to the desired thermostat set point. 

Heat  Exchanger 

Device in the base  of the furnace where the stored heat  from the brick core 
transfers to the duct system for delivery into the living space. 

Manual  Charge  Control 

Method of brick core charging regulation where the user must periodically adjust 
the brick core temperature setting in relation to the outdoor temperature. 

Off­Peak 

The time during the day or night when the power company can supply electricity 
more economically and may offer a special incentive such as a reduced electric 
rate or billing credits for the electricity consumed during this time.  Typically, 
uncontrollable electrical usage is allowed during this time.  (Furnace is allowed 
to charge or store heat in its brick core during this time.) 

On­Peak 

The time during the day or night when the power company experiences a high 
demand for electricity.  To limit demand, certain appliances are controlled to 
avoid usage by them and/or a premium for the electricity consumed during this 
time may be charged.  (Furnace is not allowed to charge or store heat in its 
brick core during this time.) 

Outdoor  Temperature  Sensor  Device that senses outdoor air temperature and communicates this information 

to the furnace for automatic charge control. 

Peak  Override 

Enables electrical usage in a device that is typically controlled by the power 
company during an on­peak time.  Some power companies may never permit 
any controlled devices to be used during an on­peak time.  Others that do may 
penalize the user by charging a premium on energy consumed during this period. 

3

General Information

(cont'd) 

TERM 

DEFINITION 

TERMINOLOGY 

This manual contains terms which may need explanation.  The table below lists some of these terms and a brief 
description of each. 

2

Advertising
This manual is related to the following products: