Troubleshooting information, Cont'd) – Steffes DLF40B User Manual

Page 32

Advertising
background image

Troubleshooting Information

(cont'd)

31 

Core  Charging 

A.    PROBLEM:  FURNACE  OVERCHARGES  ON  WARM  DAY 

Check operation of outdoor 

temperature lights on charge 

control circuit board (30). 

Check "AUTO/HIGH/LOW" toggle switch.  Unit 

should not be in HIGH mode on warm days. 

All Outdoor Temperature Lights Are "ON" 

Regardless of Outdoor Temperature 

With wires disconnected, check ohm 

values of the resistor (66).  Must be 175 

ohm center to top & center to bottom. 

Check for 32 VDC between room thermostat 

connection "C" terminal block position and top low 

voltage 1/2­amp fuse on charge control circuit 

board (30).  Check fuse. 

Replace 

resistor (66). 

Check VAC on resistor (66) from middle to top and middle to 

bottom. Reults vary depending on number of charging lights 

on: 

1 light on = 24 VAC middle to top and bottom 

2 lights on = 0 VAC middle to top; 24 VAC middle to bottom 

3 lights on = 0 VAC middle to top and bottom 

Lights Work Properly 

Ok 

Defective 

No Voltage 

Fuse Ok 

Check for 24 VAC between room thermostat 

connection "C" terminal block position and the 

two 3­amp low voltage fuses on the charge 

control circuit board (30). 

Replace charge 

control  thermostat. 

Check control 

transformers (28). 

Replace charge control 

circuit board (30). 

No Voltage 

Present 

Ok 

Replace charge control circuit board (30). 

Ok 

1.  With outdoor temperature sensor wiring disconnected, the 
"SUMMER/WINTER" toggle switch on charge control circuit board (30) set to the 
WINTER position and the "AUTO/HIGH/LOW" toggle switch set to "AUTO", 
jumper outdoor sensor terminal block positions "W" & "R".  "LEVEL 3 OUTDOOR 
TEMP SENSOR" light on charge control circuit board (30) should be off. 

2.  Jumper "W", "R", & "B" terminal block position. "LEVEL 2 AND 3 OUTDOOR 
TEMP  SENSOR" lights on charge control circuit board (30) should go off. 

Voltage 
Present 

Replace charge control 

circuit board (30). 

Replace outdoor 

temperature sensor (64) 

Defective 

Ok 

Check unit wiring and 

the charge control 

circuit board fuses. 

Repair wiring or replace fuses. 

NOTE: If fuses open again, 

change charge control circuit 

board (30). 

Incorrect Wiring 
or Open Fuse(s) 

Ok 

Incorrect 

Replace charge control 

circuit board (30). 

Ok