DEVICE  NAME 

FUNCTION 

Safety Information

LOCATION

ON HEATER

SAFETY PRECAUTIONS 

1.  DO NOT energize the furnace while disassembled or without ceramic heat storage brick in place. 
2.  As is true with all heating appliances, materials that may produce explosive or flammable gases MUST NOT 

be used  or stored near  the furnace. 

3.  Be sure the minimum clearance requirements specified in this manual are never violated. 
4.  This unit may be connected to more than one branch circuit.  Disconnect power to all circuits before servicing. 

BUILT-IN SAFETY DEVICES 

All Steffes Double Loop Central Furnaces incorporate safety devices to ensure normal operating temperatures 
are  maintained.   The  chart  below  describes these  safety  devices. 

Core Charging High 
Limit Switches 

These limit switches monitor brick core charging and will 
interrupt power to the heating elements if the normal 
operating temperature is exceeded.   Each switch controls 
two  heating  elements. 

In the limit bar panel 
on the right side of the 
brick storage cavity 

This limit switch monitors the temperature in the heat 
exchanger of the furnace.  If the normal operating tempera­ 
ture is exceeded, this switch will interrupt power to the core 
blower. 

Heat  Exchanger  High 
Limit Switch 

In the base of the 
furnace inside the 
electrical panel 

This limit switch monitors the discharge air temperature and 
interrupts power to the core blower if this temperature 
exceeds 160 

F (nominal). 

Core Blower  High 
Limit Switch 

In the supply air 
plenum assembly on 
the  blower 

This limit switch monitors the discharge air temperature and 
interrupts power to the supply air blower if this temperature 
exceeds 180 

F (nominal). 

Supply Air Blower 
Limit Switch 

In the supply air 
plenum assembly on 
the  blower 

The filter in the furnace should be replaced on a regular basis.  General cleaning of the furnace’s cabinet should be 
conducted at the user’s discretion.  No additional routine maintenance is required. 

Maintenance and Cleaning