Installing The Furnace

(cont'd)

15

LINE VOLTAGE ELECTRICAL CONNECTIONS 

In standard configuration, the furnace is wired for connection to 240V but are available with 208V or 277V 
heating elements as special factory orders.  However, the blowers and furnace controls circuit must always be 
connected to 240V or 208V. 

The furnace is set up for multiple feed circuits.  The 60 amp breakers located in the electrical compartment at 
the base of the  furnace feed the core charging (element)  circuits.  The 15 amp breaker  feeds the furnace 
controls and blowers circuit.  The furnace's elements and blowers/controls circuit can be fed with separate 
circuits or the blowers/controls can be fed from one of the element circuits.  If single feed of the charging 
(element) circuits is desired, an optional single feed kit is available from the factory.  (Order item #1309000.) 
The single feed kit enables the furnace to be fed with a single circuit which then splits this circuit internally to 
each  breaker. 

All  line  voltage  circuits  must  be  segregated  from  low  voltage  wiring  in  the  furnace. 

To determine the correct wire size required for each circuit feeding the furnace, refer to the Unit Specifications 
section in this manual.  It is the responsiblity of the installer to follow all applicable electrical codes and regula­ 
tions for the installation. 

Step  1 

Remove the electrical  panel cover (46). 

Step  2 

Route line voltage wiring through a knockout and into the electrical panel of the furnace. 

Step  3 

Make the proper field wiring connections to the furnace breakers.  (See the Line Voltage Wiring 
Diagrams in this manual for more information on these connections.) 

To  reduce  magnetic  fields  that  can  be  produced  by  electrical  circuits,  it  is  rec­ 
ommended  to  alternate  the  circuit  phases  in  the  furnace.    (See  Figure  8  for  more 
information  on  how  to  phase  connect  the  circuits.) 

8

NOTE

NOTE