Troubleshooting Information

(cont'd)

32 

B.    PROBLEM:    FURNACE  WILL  NOT  CHARGE  (FURNACE  HAS  NO  CORE  CHARGE) 

Check power company load control switch 
& furnace "OFF­PEAK" light on the charge 

control circuit board (30) for proper 

operation.  Continue following 

procedures in off­peak mode. 

Check "outdoor temp 

SENSOR" lights on the 

charge control circuit 

board (30). 

Check "ETS CHARGING" 
light on the charge control 

circuit board (30). 

Check for 24VAC on 

orange wire going to the top 

staging sequencer (24). 

Check for 

defective charge 

sequencers (26) and 

for defective heating 

elements (17). 

Check unit wiring 

and/or replace 

charge control 

circuit board (30). 

Check for 24 VAC between each of the two 

bottom 3­amp low voltage fuses and the room 

thermostat connection "C" terminal block 

position on charge control circuit board (30). 

Lights Inoperable 

Lights 

Operable 

Off 

On 

Voltage  Present 

No  Voltage 

Jump charge control thermostat 

(32) brown lead to charge 

control thermostat orange lead. 

Replace charge control 

circuit board (30). 

Replace charge 

control thermostat 

(32). (NOTE: 

Make sure charge 

control thermostat 

shaft is in the full 

clockwise position.) 

Check outdoor temperature. 

Set the "AUTO/HIGH/LOW" 

toggle switch on charge 

control circuit board (30) to 

high position. 

Check supply 
voltage to the 

control 

transformer(s) (28) 

and unit wiring. 

Set the "AUTO/HIGH/LOW" toggle switch to "AUTO" and the 
"SUMMER/WINTER" toggle switch to "WINTER" positions on the 
charge control circuit board (30): 

1.  Remove outdoor sensor wire connected to the  "G" terminal 
position.  "Outdoor temp SENSOR LEVEL 1" light should be "ON". 

2.  Remove outdoor sensor wire connected to the "B" terminal 
position.  "Outdoor temp SENSOR LEVEL 2" light should be "ON". 

Replace charge control 

circuit board (30). 

Retest. 

One or More 

Lights on 

No 

Lights 

Charge Light 

"OFF" 

Charge 

Light "ON" 

Below 55 

Outdoor 

Temperature 

Above 55 

Outdoor 

Temperature 

Voltage Not Present 

On One or Both 

Both Fuses 

Energized 

Repair wiring. 

Check secondary 

voltage from control 
transformer(s) (28). 

Ok 

Defective 

Replace outdoor air 

temperature sensor (64). 

Replace charge control 

circuit board (30). 

Ok 

Defective 

Replace 24 VAC control 

transformer(s) (28). 

Replace charge control 

circuit board (30). 

No  Voltage 

Ok 

Jump orange leads 

to the auxiliary 

control board. 

Charge Light 

"OFF" 

Go to Auxiliary Control Board 1302038 

­ Furnace Will Not Charge Continued. 

Charge 

Light "ON"