Furnace Control Panel

(cont'd) 

SUMMER/WINTER  Toggle  Switch 
This toggle switch will vary core charging in the furnace.  It allows for a reduced heating capacity during the summer 
months if the user prefers to leave the furnace "ON" for emergency heat purposes during this time.  (Refer to Table 1, 
Brick Core Charging Schedule, in this manual for more information on charging levels in relation to the position of this 
switch and outdoor temperature.) 

AUTO/HIGH/LOW  Toggle  Switch 
This toggle switch can be used to override the automatic outdoor temperature sensing system. 

AUTO =  Normal operating position.  The brick core charge level is controlled automatically by the outdoor 

temperature  sensor. 

HIGH  =  The furnace will target a level 3 (maximum) core charge during an off­peak time regardless of the 

outdoor temperature information it is receiving. 

LOW  =  The furnace targets a minimum of a level 1(1/3) core charge during an off­peak time unless the 

outdoor temperature sensor is signaling for a higher charge level. 

OVERRIDE  Light  (Power  Company  Permitting) 
This red light illuminates whenever a peak control override is initiated and remains illuminated for the duration of the 
override period. The function of the override indicator light works in conjunction with START and CANCEL toggle 
switches. 

START  and  CANCEL  Toggle  Switches  (Override  Feature,  Power  Company  Permitting) 
The furnace has a built­in peak override feature. This feature allows the heating elements in the furnace to come "ON" 
during a peak control time provided the power company permits the use of this option. Since not all power companies 
permit use of the override option, all furnaces are shipped with this feature disabled. If the feature is enabled in the 
furnace, these toggle switches initiate and cancel the override of a peak control time. 

START 

= Initiates an override of a peak control time allowing the heating elements to come "ON".  The 

furnace targets a level 1 (1/3) core charge during an override cycle.  If initiating the peak 
control override feature, the override will only last for the duration of the peak control period at 
which time it resets itself automatically unless the user manually cancels it prior to then.  (The 
override light will illumniate if the START switch is toggled.) 

CANCEL  = Allows for manual cancellation of a peak override any time during an override cycle.  An 

override cycle will automatically cancel itself at the start of the next off­peak period. 

The  peak  override  option  may  not  be  available  in  your  area.    Please  consult  your  power 
company  if  you  are  unsure  of  whether  this  option  is  available  to  you.    If  so  and  you  desire 
to  enable  the  feature,  contact  your  power  company  for  instructions. 