# 2 Checkweigh: Under/Between/Over

The indicator monitors the scale for activity, when the scale goes above the

‘empty’ weight, the indicator waits for a stable weight, and then outputs an

indication of Under, Between (OK), or over. The cycle resets when the scale

goes below the empty weight.

Installation

Connect TTL outputs to relays or lamp actuators.

Under weight indication

TTL 1

TB4 - Pin 1

Between weight indication

TTL 2

TB4 - Pin 2

Over weight indication

TTL 3

TB4 - Pin 3

Ground

GND

TB4 - Pin 4

+ 5 volts DC +5v TB3 - Pin 1

Configure ‘empty’ scale weight. (Parameter 43)

Operators Functions

Enter setpoint weights

Press the F1 key. The display prompts “SP 1. Use the numeric keyboard to

enter setpoint 1, then press the ENTER key. The display prompts “SP 2”. Use

the numeric keyboard to enter setpoint 2, then press the ENTER key. NOTE:

use the F2 key to enter a decimal point if needed.

Recalculate

Press the F2 key to re-check the weight on the scale after adjustments have

been made to the weight.