REBUILD ID MEMORY:

Press the ENTER key when the display prompts,

“rebuiLd”. The display then prompts “id”. Enter the numeric 0 then press ENTER

to rebuild ID memory.

COUNT UNUSED ID’S:

Press the ENTER key when the display prompts

“Count”. The display prompts “FrExxx” where xxx is the number of unused ID

records in memory.

Set Beginning Sequence Number

Depress the number 9 key and then the ENTER key. The display prompts "reg 9"

for 1 second and then displays the current value. Press the CLEAR key if no

change is to be made, or enter a new value and then press the ENTER key. The

next sequence number printed will be the entered value +1.

Options

Print key

: Set parameter 52 = 4 (execute user function 4) to enable the print

key to print the weight on the scale. The print data is sent to Serial

Communications Port 1. If units other than lb are used, change print label 85

to the correct units. (This option is not available for printers that use the

parallel output port).

Unit’s key

: Set parameter 53 = 127 (execute Units function) if weighing of

dual units is required.

Notes

The ID file maintenance functions are password level 1 protected. If a

password has been configured (function 64) the operator will be prompted for

the password before the file maintenance menu is displayed.

ID memory is cleared to zero at power up unless CFG parameter 41 (battery

back up enable) is set to 1.