Industrial Data Systems IDS 430 User Manual

Page 4

Advertising
background image

Parameter 15. Alternate Count-By (5)

34

Parameter 16. Alternate Units Conversion Factor (45,360)

34

Parameter 17. Full Scale Graduations (10,000)

34

Parameter 18. Overload Graduations (10,200)

34

Parameter 19. Deadload Offset (automatically set)

34

Parameter 20. Disable Power-on Zero (1[power-on zero disabled])

35

Parameter 21. Deadload Factor (automatically set)

35

Parameter 22. Weight Conversion Factor (automatically set)

35

I/O Port Parameters

35

Parameter 23. Serial Port 1 Mode (4[8 data bits, no parity])

35

Parameter 24. Serial Port 1 Baud Rate (1[9600 baud])

36

Parameter 25. Serial Port 2 Mode (4[8 data bits, no parity])

36

Parameter 26. Serial Port 2 Baud Rate (1[9600 baud])

36

Parameter 27. TX2 Control / Station ID (255[single station])

37

Parameter 28. TX2 Format (2[Condec data format])

37

Printer Parameters

38

Parameter 30. Auto Line Feed after Carriage return (1[yes])

38

Parameter 31. End of Print Character (12[form feed])

38

Parameters 32, 33, 34, 84, 85, 86, 87, 88 and 90 Print Labels

38

Parameters 35, 36, 37 and 38. Print Codes

39

Parameter 39. TTL Remote Control (1[ttl in = scale basic function])

39

Display Intensity, Watch Dog Timer

40

Parameter 40. Display intensity (10)

40

Parameter 41. Battery Enable (0[optional clock needed])

40

Parameter 42. Enable Watch Dog Timer (0)

40

Fixed Registers

40

Parameter 43-50. Fixed Registers

40

Keyboard Events

40

Parameters 51-58. Keyboard Event Functions

40

PARAMETER FUNCTIONS

41

Function 59. Display Calibration Audit Number

43

Function 60. Calibrate Scale (deadload first)

43

Function 61. Calibrate Scale (span first)

43

Function 62. Calibrate (deadload only)

44

Function 63. Adjust Gain Calibration

44

Function 64. Configure Passwords

45

Function 65. Configure Print Formats

46

Function 66. Configure Time and Date

51

Function 67. Display Operation Parameters

51

Function 68. Print Operation Parameters

51

Function 69. Diagnostic Tests

52

Function 70. Initialize Operation Parameters to Factory Default

52

Function 71. Configure Event monitor

53

Function 72. Scale Basic Function Editor

53

Function 73. Select Mode of Operations

54

Function 74. Configure Timers

55

Function 75. Enable Peak Detect

55

Function 76. Debug Mode

55

Function 78. Initialize ID Memory

55

Function 79. Enable Multi-point Linearization

55

Function 80. Multi-point Linearization Calibration

56

Advertising
This manual is related to the following products: