- 54 -

Function 73 Initialize Function Memory

The initialize function erases function memory and setpoint monitor memory, and

initializes all parameters with password level 1 or 2.
Function 73 prompts “rs Fn” . Press the Enter key to initialize only or enter a

number below to activate a built in program.
1. Fill to Setpoint.

2. Checkweigh: Over/Between/Under

3. Weigh-in / Weigh-out

4. Axle Weigh – Short Scale

5. Axle Weigh – Long Scale

6. ID Tare and Total

7. Peak Hold