Hardware installation and wiring – Industrial Data Systems IDS 430 User Manual

Page 63

Advertising
background image

IDS 430/433 Users Manual Version 1.0

- 63 -

HARDWARE INSTALLATION AND WIRING

This section describes installation and wiring information for the interface ports.

There are two bi-directional serial ports, digital port with 3 TTL inputs, 3 TTL

outputs, and one load cell input port. The serial ports are used to interface to a

printer and to a host device or PC for continuous output. The TTL outputs and

inputs are used for remote switch input and relay control. The load cell input is

used to interface to the scale platform.

Load Cell Connector – TB1
NOTE

: Remove jumpers JP1 and JP2 to enable SENSE LINES for 6 wire load

cells. Wire the sheilding from the load cells to the chassis not TB1 pin 7.

Load Cell Terminal Block – TB1

Pin #

Signal Name

1

+ Signal

2

- Signal

3

+ Excitation

4

+ Sense

5

- Sense

6

- Excitation

7

Analog ground

(NOT FOR SHIELD)

Power Source AC / DC

The unit comes standard with an onboard transformer the AC interface

connector is a 3 pin Molex type, this connects to the motherboard where

the 3 pin Molex header is mounted on the board marked A/C power.


For DC power applications there ia a 2 position terminal block marked

PWR-DC. Note the polarity of the terminals. The positive is marked as ( + )

the negative ( - ). The DC power input will exept +12 to +28 VDC. Remove

AC power before wiring for DC.

I/O Port Connector - TB 3

The I/O port connector has Com Ports 1 and 2 and the digital TTL inputs.

Pin #

Signal Name

1

+5V (CL2 TX +)

2

TXD 1 (RS232)

3

RXD1 (RS232)

4

Soft +5 volts (220 ohm to +5V)

5

GND (CL1 TX-)

6

CL1 TX +

7

GND

8

TTL IN 1

9

TTL IN 2

10

TTL IN 3

Advertising