Specifications, Standard features, Modes of operation – Industrial Data Systems IDS 430 User Manual

Page 67

Advertising
background image

IDS 430/433 Users Manual Version 1.0

- 67 -

SPECIFICATIONS

STANDARD FEATURES

SCALE SPECIFICATIONS

Display

Bright red LED; 1-inch x 6-digit numeric

Status Indicators

Gross, Net, Motion, Zero, LB, Kg (LED)

Keyboard

19-key sealed tactile feel membrane

Internal Resolution

20-bit A/D Sigma-Delta; 1,048,000 d

Display Resolution

120,000 dd industrial; 10,000 dd HB44

Display increments

Selectable 1, 2, 5, 10,20, 50 100

Decimal Point

Selectable 0, 1, 2, 3, 4 decimal places

Conversation Rate

60 samples/second typical

Signal Sensitivity

0.1 uV/graduation (min)

Signal Range

0.5 mV/V to 6mV/V

Load Cell Excitation

10

±

0.5VDC (-5 to +5)

Load Cell Power

12 x 350

or 24 x 700

load cells

Auto Zero Tracking

0-60 dd in 1/4 dd increments

Auto Zero Delay

0-25 seconds In 0.1 second increments

Motion Detect

0-60 dd in 1/4 dd increments

Motion Delay

0-25 seconds In 0.1 second increments

Digital Filter

0-18 selectable filter (DSP) levels

Calibration

Selectable multi-point (up to 5) digital

calibration to linearize input signal

Watchdog Timer

Enable/disable fault tolerant operation

RFI Protection

Signal, excitation and sense lines

RAM

32K provides 500 ID storage (parts, etc)

COMMUNICATIONS

Serial Port 1

Simplex RS232 or 20mA current loop

Serial Port 2

Full duplex RS232 or RS485

Digital Port

3 inputs and 3 outputs; Low active (TTL)

Print Formats

4 user configurable print formats

GENERAL SPECIFICATIONS

Power

110/220VAC ±10% @ 50/60Hz

or 12-28 VDC

Power Consumption

10W @ 115VAC; 6W @ 12VDC

Operating Temperature -10 to +40

o

C.

Weight

6 lbs (2.72 kg)

Warranty

One year limited

OPTIONS

Analog Output Module

Fully isolated 0-10VDC or 4-20mA; 16-bit

resolution; 650

load resistance

Relay Board

4-channel external relay enclosure

Relay Modules

Input/output solid-state (AC/DC) relays

Clock Module

Time & Date clock Y2K and Leap Year

High speed (HS)

100 samples/second conversion rate;

High speed process control applications

EZ-LINK

PC software; Facilitates configuration

and Scale Basic programming

IS Barriers

Hazard location intrinsic safety barriers

MODES OF OPERATION

The IDS 430/433 is a versatile indicator for use in various industries

and applications that can range from basic weighing, material testing

to more complex formula batch weighing. The IDS 430/433 is

housed in a rugged stainless steel enclosure and provides a

universal mounting bracket for wall or desk mounting. The viewing

angle can be adjusted for the best possible view of the weight. The

bright red 1 inch high LED display makes it easy to read the weight

from longer distances compared to other indicators. The keyboard

features large keys, which give you tactile and audible confirmation

of data entry. The IDS 430/433 is programmable in an easy and

flexible macro language called Scale Basic

. In addition to the built-

in modes of operation, Scale Basic allows you to customize the

operation of the IDS 430/433 to meet your application requirements.

The Scale Basic language provides various commands and

functions that include: math operations, I/O control, setpoints,

timers, data entry, id storage, message display, and program

sequence control among others. Programming the IDS 430/433 can

be performed through the keyboard or a PC using the optional EZ-

LINK

software that greatly facilitates setup and programming.

MODE 0 - Normal

Basic gross, tare and net weighing

MODE 1 – Fill to Setpoint

Single setpoint fill with relay output control and weight print

MODE 2 - Over/Under Checkweigh

Provides 3 TTL outputs and 2 setpoints to indicate over,

under and between weight conditions. Outputs can activate

lights or alarms

MODE 3 – Vehicle Weigh-In/Out with Totals

Weigh-In/Out program for up to 500 vehicles, maintains

running totals for each vehicle and provides reporting

functions

MODE 4 - Multi-Container/Axle Auto Weighing

Auto weighs and prints each weight placed on the scale, each

weight is sequentially numbered and accumulated, the total

can be printed manually or automatically and provides traffic

light control

MODE 5 - Auto Axle Weigh (Long Scales)

Same as Mode 4 but previous axles are auto tared

MODE 6 – ID Tare, Print and Total

Provides tare entry and recall by ID, prints ID, sequence #

and GTN weights, keeps running totals by ID, provides

reporting functions

MODE 7 - Peak Hold Mode

Display or print the peak gross or net weight detected

A = 7.63” (19.38 cm)

B = 6.88” (17.48 cm)

C = 8.56” (21.74 cm)

D = 2.00” (5.08 cm)

E = 3.00” (7.62 cm)

D

E

12345

A

B

C

Advertising
This manual is related to the following products: