7 peak hold function – Industrial Data Systems IDS 430 User Manual

Page 26

Advertising
background image

IDS 430/433 Users Manual Version 1.0

- 26 -

# 7 Peak Hold Function

The peak hold register maintains the peak weight detected by the weight

indicator.

Enable Peak Hold

Access configuration parameter 75. Enter a 1 to enable peak hold, enter a 0 to

disable peak hold.

Clear Peak Hold Register

Press the CLEAR key to reset the peak hold register to 0.
Use the Scale Basic built in function Clear Peak [143] to reset the peak hold

register.

Display Peak Weight

Use the GROSS/NET key to scroll thru the display options as follows:

Initial mode:

Display gross weight. Gross LED on.

First GROSS/NET press:

Display net weight.

Net LED on.

Next GROSS/NET press:

Display gross peak weight. Gross LED flashing.

Next GROSS/NET press:

Display net peak weight. Net LED flashing.

Next GROSS/NET press:

Display gross weight.

Gross LED on.

Etc.

Print Peak Weight

Use function 65 (Configure Print Formats) to format the print output using page 1:

Print Item 19:

Print Gross Peak weight on page 1.

Print Item 20:

Print Net Peak weight on page 1.

Advertising