2 i/o communication – KEYENCE DL-DN1 User Manual

Page 38

Advertising
background image

3-2 I/O Communication

3-8

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -

3

Co
mm

u

ni

c

a

ting
w

ith t
he G

T

2

s

er

ie

s

Status details

Error information list

Name

Description

Reading range

Error status

An error occurred with the DL-DN1 or sensor amplifier, or the
DL-DN1 is not communicating properly with the sensor amplifier.
If an error exists, the error ID number and error code are stored.

0: No Error
1: Error

Sensor ready

The sensor amplifier has started and is ready.

0: Starting
1: Ready

Error ID number

The error ID number is stored in the range of bit 0 (LSB) to bit 4
(MSB).

"Error information list"

(page 3-8)

Error code

The error code is stored in the range of bit 8 (LSB) to bit 12
(MSB).

Error ID

number

(HEX)

Error
code

(HEX)

Description

Cause

Corrective action

00h

01h

Initialization error

Error encountered during
initialization.

Check the number of
connected sensor amplifiers
and the connection to the
sensor amplifiers, and then
cycle power. If the error
remains, contact your nearest
sales office.

04h

Mixed connection error

A foreign sensor amplifier (i.e.,
one that is not compatible) is
connected.

Remove the foreign sensor
amplifier.

06h

Number-of-units error

More sensor amplifiers are
connected than are permitted.

Check the number of
connected sensor amplifiers.

nnh

(01h -

0Fh)

01h

Error 1 for sensor amplifier of
ID number nn

Overcurrent error (ErC)

Refer to the GT2 series user's
manual.

02h

Error 2 for sensor amplifier of
ID number nn

Head error (ErH)

03h

Error 3 for sensor amplifier of
ID number nn

EEPROM error (ErE)

04h

Error 4 for sensor amplifier of
ID number nn

Jam check error (Er.chK)

05h

Error 5 for sensor amplifier of
ID number nn

Self-timing delay error (Er.dLY)

06h

Error 6 for sensor amplifier of
ID number nn

Number-of-units error (Er.Unit)

07h

Error 7 for sensor amplifier of
ID number nn

Calculation error (Er.CAL)

08h

Error 8 for sensor amplifier of
ID number nn

Calculation-only mode error
(Er.noH)

1Dh

02h/
04-07h

System error

An error occurred in the internal
system.

Check the connection to the
sensor, and then cycle power. If
the error can not be corrected,
contact your nearest sales
office.

03h

Model error

There is a sensor amplifier
connected that is incompatible
with the DL-DN1.

Connect a sensor amplifier of a
compatible model.

1Fh

-

No error

-

-