3 explicit messaging, Co mm u ni c a ting w ith t he g t 2 s er ie s – KEYENCE DL-DN1 User Manual

Page 62

Advertising
background image

3-3 Explicit Messaging

3-32

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -

3

Co
mm

u

ni

c

a

ting
w

ith t
he G

T

2

s

er

ie

s

Nx10+4

72

Display resolution

R/W

0

0: 0.0001

1: 0.001

2: 0.01

3: 0.1

73

Hysteresis

R/W

+000.0030 +000.0000 to +199.9999

74

Simultaneous input setting

*12

R/W

0

0: Individual input

1: Simultaneous input

75

Special output setting

*8

R/W

0

0: Do not use

1: 5-output

2: Limit output

3: Limit output user setting

4: GO for all

5: Limit output for all

76

Limit output switch (HH) position

*8

R/W

+000.0000 -199.9999 to +199.9999

77

Limit output switch (LL) position

*8

R/W

+000.0000 -199.9999 to +199.9999

78

Select preset data

R/W

0

0: R.V. value

1: P.V. value

79

Preset memory

R/W

0

0: YES

1: NO

7A

Preset point

R/W

0

0: Common to all banks

1: Store separately for each bank

7B

Power-saving function (ECO)

R/W

0

0: OFF

1: HALF

2: ALL

7C

Jam detection function

R/W

0

0: OFF

1: ON

2: USER

7D

Jam detection position

R/W

+000.5000 -199.9999 to +199.9999

7E

Batch setting (GT2-100* only)

*14

R/W

0

0: Individual

1: Batch

7F

Analog range setting

*15

R/W

0

0: Default

1: Free range setting

80

Free range setting (Hi)

*15

R/W

+012.0000 -199.9999 to +199.9999

81

Free range setting (Lo)

*15

R/W

+000.0000 -199.9999 to +199.9999

82 to

83

System reserved

Nx10+5

64

Group-5 entry count

R

15

65

R.V. value of main unit (ID: 01) on
which calculation result was based

*3
*6

R

66

R.V. value of expansion unit (ID: 02)
on which calculation result was
based

*3
*6

R

67

R.V. value of expansion unit (ID: 03)
on which calculation result was
based

*3
*6

R

68

R.V. value of expansion unit (ID: 04)
on which calculation result was
based

*3
*6

R

69

R.V. value of expansion unit (ID: 05)
on which calculation result was
based

*3
*6

R

6A

R.V. value of expansion unit (ID: 06)
on which calculation result was
based

*3
*6

R

InstID
(DEC)

AttrID

(HEX)

Name

Description Attribute

Default

value

Parameter range

Advertising