Rewriting a Setting Value of a Sensor Amplifier

Available setting values: HIGH setting value, LOW setting value, PRESET setting
value, HH setting value, and LL setting value

Device assignments:

"Rewrite setting value" (page 3-14)

The setting values to be rewritten are those listed above, which are
stored in bank 0. When rewriting the setting values in banks other

than bank 0, use the procedure described in

"Reading/Writing Set-

tings or Status of a Sensor Amplifier" (page 3-24).

When rewriting any setting or parameter other than listed above, use the

procedure described in

"Reading/Writing Settings or Status of a Sensor

Amplifier" (page 3-24).

This example changes the HIGH setting value of ID01.
It assumes that the operating mode assigned to the device is 3-output mode.
(1) Write the new setting value in the "setting-value rewrite data. "For details of

writable ranges, see

"Command Parameter List for GT2 Series" (page 3-28).

(2) Execute the "request to rewrite setting value" command (0 -> 1).
(3) After the setting value is rewritten, the "setting value rewrite complete" signal flips

from 0 to 1.

(4) If an error occurs during "setting value rewriting " on the sensor amplifier, the

"setting value rewrite error" signal flips from 0 to 1. (The output is an OR sum of
settings.) Check the value entered in the "setting-value rewrite data."

(5) When the "request to rewrite setting value" command is set to 0, the "setting value

rewrite complete" and "setting value rewrite error" parameters flip to 0.

Point

Reference

PLC

(1)

Setting-value rewrite data

1234h

Out area [m+4 to 5]

(2) (5)

Request to rewrite setting value

Out area [m+3] BIT 0

(3)

Setting-value rewrite complete

IN area [n+8] BIT 0

(4)

Setting- value rewrite error

IN area [n+7] BIT 0