Command parameter list, Command parameter list -27, Common command parameter list – KEYENCE DL-DN1 User Manual

Page 57: 3 explicit messaging, Co mm u ni c a ting w ith t he g t 2 s er ie s

Advertising
background image

3-3 Explicit Messaging

3-27

3

Co
mm

u

ni

c

a

ting
w

ith t
he G

T

2

s

er

ie

s

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -

The following tables list the command parameters used in explicit messaging to read/
write the settings and status of sensor amplifiers and to issue motion commands.
For details about how the master unit performs explicit messaging using command
parameters, see:

"Issuing a Motion Command to a Sensor Amplifier" (page 3-23)

"Reading/Writing Settings or Status of a Sensor Amplifier" (page 3-24)

Common Command Parameter List

The table below describes command parameters which are common to the DL-DN1.
InstID: Instance ID; AttrID: Attribute ID
Attribute R: Read; R/W: Read/Write

Command Parameter List

InstID
(DEC)

AttrID

(HEX)

Name

Description

Attribute

Data

type

Default

value

Parameter range

0

64

Status

Bit 0 - 12: Unused
Bit 13: Sensor ready
Bit 14: Warning state
Bit 15: Error state

R

WORD

0

*1

65

Error state

The error state values of sensor amplifiers
(ID 01 to ID 15) are output as they are
assigned to bits 0 - 14.

R

WORD

0

0: No Error
1: Error

66

Warning state

Not used with the GT2 series.

R

WORD

0

67

System reserved

68

Current value
property

This property is output by assigning sensor
amplifiers (ID 01 to ID 15) bits 0 - 14.
The output occurs when the measured
value is non-numeric: "over," "under," or
"invalid."

R

WORD

0

0: Normally mea-
sured value
1: "over," "under," or
"invalid"

69 to 6B System reserved

6C

Error ID number Error details.

If there are errors with multiple ID numbers,
the error information for the smallest ID
number is output.

R

UINT

0

*2

6D

Error code

R

UINT

0

6E

Warning ID
number

Not used with the GT2 series.

R

UINT

0

6F

Warning code

R

UINT

0

70 to 73 System reserved

74

HIGH

The HIGH state is output by assigning sen-
sor amplifiers (ID 01 to ID 15) bits 0 - 14.

R

WORD

0

0: OFF
1: ON

75

LOW

The Low state is output by assigning sen-
sor amplifiers (ID 01 to ID 15) bits 0 - 14.

R

WORD

0

0: OFF
1: ON

76

GO

The GO state is output by assigning sensor
amplifiers (ID 01 to ID 15) bits 0 - 14.

R

WORD

0

0: OFF
1: ON

77

HH

The HH state is output by assigning sensor
amplifiers (ID 01 to ID 15) bits 0 - 14.

R

WORD

0

0: OFF
1: ON

78

LL

The LL state is output by assigning sensor
amplifiers (ID 01 to ID 15) bits 0 - 14.

R

WORD

0

0: OFF
1: ON

79 to 8C System reserved

8D

Comparator
value "invalid"

If the comparator values for sensor amplifi-
ers (ID 01 to ID 15) are invalid
(-----), they are output by assigning them to
bits 0 - 14.

R

WORD

0

0: Normal value
1: Invalid

Advertising