3-3 Explicit Messaging

3-31

3

Co
mm

u

n

ic

a

tin

g

with

th
e

GT2

s

e

rie

s

- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -

Nx10+4

64

Group-4 entry count

R

29

65

Calculation mode/calculation setting

*12
*13

R/W

0

00+m: Do not use calculation function

10+m: Use calculation function

20+m: Calculation-only mode

0: Maximum

1: Minimum

2: Flatness

3: Mean

4: Standard difference

5: Torsion

6: Warp

7: Thickness

66

Detection mode

R/W

0

0: Standard

1: NG hold

2: Peak

3: Bottom

4: Peak-to-peak

67

Hold update method

R/W

0

0: Timing

1: Always update

68

Response time

R/W

3

When the connected
sensor head is
GT2-H***/A***

When the
connected sensor
head is GT2-P***

0: HSP (3.0 ms)

HSP (12 ms)

1: 5 ms

20 ms

2: 10 ms

40 ms

3: 100 ms

400 ms

4: 500 ms

2000 ms

5: 1000 ms

4000 ms

69

Timing type

R/W

0

0: External timing input

1: Rising self

2: Falling self

6A

Self timing level

R/W

+000.5000 -199.9999 to +199.9999

6B

Self-timing delay type

R/W

0

0: Static hold

1: Delay timer

6C

User-specified delay time

R/W

1000

0000-9999

6D

Static hold delay stable determination

R/W

0

0: Default

1: User

6E

Static hold delay stable range

R/W

+000.0100 +000.0000 to +199.9999

6F

Measurement increase/decrease
direction

R/W

0

0: Normal

1: Reverse

70

Multiplier

R/W

001.0

000.1 to 100.0

71

Output mode

R/W

0

0: NO

1: NC

InstID
(DEC)

AttrID
(HEX)

Name

Description Attribute

Default

value

Parameter range

Advertising