ALTANA Micro-Wave-Scan Manual User Manual

Page 37

Advertising
background image

36

Configuration

9.3 Scale

Up to 10 scales may be selected for the display of

the measurement results.
Select the desired scale to be changed and press

the operate button.

Following scales are available:
Longwave

(0...100)

Shortwave

(0...100)

The classical scales

Longwave (1,2 - 12 mm) and

Shortwave (0,3 - 1.2 mm)

DOI (Dorigon)

(47...96)

Correlation to ASTM E 430, value range similar to

20° gloss.

DOI (GM)

(47...96)

GM specification

DOI (BYK)

(30...100)

Higher resolution but lower values than DOI

(Dorigon)

du

(1...60)

Dullness, fine structures smaller than 0.1 mm

Wa...Wd

(0...100)

The structure spectrum is evaluated by applying

filter functions to the measured optical profile.

The values Wa...Wd stand for the respective

wavelength/range.