Ecler ECLERNET MANAGER User Manual

Page 120

Advertising
background image

120

7.10.3. Configuring an ANALOG-type remote control

The third type of remote controls compatible with MIMO88 is analog such
as WPVOL-SR (wall panel with knobs performing as volume control and
sound source selector). The INPUT source selector has 5 possible
positions (OFF, 1, 2, 3 and 4). The LEVEL volume control is continuous
from 0 to 100%.

This type of control is connected to the MIMO88 unit via its GPI ports, not
via the digital bus. A GPI port is required for the volume control and another
one for the source selector. Additionally, you can connect an external switch (not included in the
WPVOL-SR) to a third GPI to perform the X-FOCUS MUTE function (muting the selected sound source).

The settings for a WPVOL-SR type analog control are performed as follows:

To configure a WPVOL-SR type analog control, you must first include an ANALOG unit in the REMOTE
LIST. See section: 7.10. MIMO88 REMOTES section



Note: analog controls are passive and therefore not automatically detected by the application,
contrary to what happens with the digital WPTOUCH and MPAGE16.

Advertising