Ecler ECLERNET MANAGER User Manual

Page 171

Advertising
background image

171

9.3.6. DELAY

The DELAY section allows you to set an independent delay time for each channel,
which is applied between input and output.
The delay time can be specified in different units, selected with the UNITS
parameter. Available units are milliseconds, seconds, centimetres and meters. The
DELAY can be set between 0 and 1000 milliseconds.

To avoid weird and annoying noises in the output signal, the value change made with the DELAY
potentiometer is not effective until the mouse button is released. At that time audio will be temporarily
muted (for a variable time, depending on the delay value used) for the new setting to be effective.


9.3.7. OUT LEVEL

Displays parameters and settings related to the output level of the channel:

 ENABLED: signal presence indicator (green) at the channel input

 LEVEL: when a front panel LEVEL control and/or a GPI port are assigned to the volume control

of a channel, the LEVEL window displays in decibels the attenuation applied to the channel
output, due to the setting of the LEVEL control and/or GPI port in question, considered as
connected "in series". In the above example we see that a global attenuation of 30 dB is applied.

 MIN and MAX: lower and upper limits fixed for any LEVEL and/or GPI volume control associated

with the channel. In the above example, whether you choose a LEVEL control, a GPI control, or
both to control a channel volume, the overall volume range applied to the channel is always
between -30 dB and -10 dB.


9.3.8. CONFIG

Channel configuration.

Clicking on the configuration edit icon opens the channel parameter setting window:








Advertising