Ecler ECLERNET MANAGER User Manual

Page 140

Advertising
background image

140

o AND: all stimuli should be = 1 to obtain 1 at the output (event triggering)
o OR: one or more of the stimuli must be = 1 to obtain 1 at the output
o OR (exclusive OR): only one of the stimuli must be = 1 to obtain 1 at the output
o NAND: (negative AND): you get a 1 at the output when at least one of the input stimuli is = 0 (a 0

is obtained when all stimuli are = 1)

o NOR (negative OR): inverse of an OR gate. All stimuli should be = 0 to obtain 1 at the output
o XNOR: (negative exclusive OR): you get a 1 at the output when all stimuli are = 1 or all are = 0


Then you must define each input stimuli up to a maximum of 4:

For each of them it's necessary to select the input (GPI, EVENT OUTPUT...) and the
DIRECT/REVERSE polarity (0 VDC for 0 and 10 VDC for 1, or vice versa), exactly as for simple digital
events. Using EVENT OUTPUT as input for one of the stimuli allows you to concatenate stimuli and thus
to exceed the limit of 4 stimuli combined with a logical operator to operate on the same target.

Note: to select the F1 or F2 key of a MPAGE16 station as input for a digital event, you must first create a
simple event with this key as input and link its output to one of the inputs of the compound digital event.
This is because F1 and F2 keys can't be assigned to a TOGGLE or PUSH operation until they are
processed by a simple digital event.

Finally, you need to define what will be the event output or target and the TOGGLE or PUSH behaviour,
also exactly as for a simple digital event:

Advertising