Ecler ECLERNET MANAGER User Manual

Page 48

Advertising
background image

48


5.4. Table of status monitoring and alarm icons

Icons indicating the status of any system function or any alarm triggering appear in different windows:

Device disconnected.
Steady red: the device has been manually disconnected (with Disconnect option).
Blinking red: EclerNet Manager tried to connect to the device, but this one is not available.

Device connected.
Blinking green.
The device is correctly connected to EclerNet Manager.

Device connected and synching.
The device is establishing the connection to EclerNet Manager.

Device connected with warning.
The device is connected, but there is a problem.
If the icon is displayed in a device status area, then another icon indicates the kind of problem
(invalid EclerNet protocol version, unsynched, etc.).
If the icon is displayed in a channel status area, it’s indicating a problem with the device (it is
recommended to consult the device status area for more information).

Invalid EclerNet protocol version.
The current version of EclerNet Manager does not allow its connection to networked devices
(Version mismatch between software and firmware). Therefore no connection can be
established, but it is possible to upgrade the firmware from Project Explorer Helper.

Invalid password.
The password entered in the device is incorrect.

Device unsynched.

The two icons are alternatively displayed.
Hardware content (state, presets ...) does not match the device content in EclerNet Manager.

Device powered.
The device is switched on (POWER ON).

Channel protect alarm.
The electronic protection alarm is activated for the channel. It lights up for a few seconds
during the boot sequence and it’s normal.

Channel thermal alarm.
The thermal protection alarm is activated for the channel.

Channel load alarm.
The impedance load protection alarm is activated for the channel.

Device mains voltage alarm.
The AC power voltage alarm is activated for the device.

Device system error.
Device error alarm (some component inside the device is malfunctioning)

Device system fault.
Device malfunction alarm (blown fuse, protection system permanently triggered, etc.).
This alarm appears along with a fault window in the device LCD.

Slave link fault.
MASTER-SLAVE connection between two MIMO88s is not valid (physical link between the
LINK BUS connector on the back panel of both MIMO88 units and crossover CAT5 cable).
Possible Causes:

 Connection is lacking or is defective

The rear panel switch of the SLAVE unit is not on SLAVE position

Invalid Slave version.
Software
- firmware version mismatch in the SLAVE unit of a pair of MIMO88s.


Note: some of these icons are device dependent, being only available for some series and/or models.