Ecler ECLERNET MANAGER User Manual

Page 93

Advertising
background image

93


3. Place the pot on the end that provides a maximum reading (in our case 83)
4. Click on the Read Current GPI value button:

5. Accept the changes with OK.





A GPO port (General Purpose Output) is a relay with a common contact and two contacts: NO (Normally
Open, with the relay at rest) and NC (normally closed, with the relay at rest). From the GPIs/GPOs
section it is possible to enable or disable the GPO ports of a MIMO88 unit by clicking on them. When you
activate a GPO, contacts are reversed: contact closes for NO and opens for NC. Contacts at rest are
filled in grey and active contacts light up in green:

In the picture the GPO 1, 4, 5 and 7 are active and the rest of them are inactive


GPO status (active or inactive) is stored in the Presets, so that recalling one of them also recalls the
existing combination of active/inactive GPOs at the time of storage.

GPO management can also be done from the EVENTS section of EclerNet Manager (see 7.12. MIMO88
EVENTS section
).

See the MIMO88 hardware manual to know current limitations of GPO ports.

Advertising