Ecler ECLERNET MANAGER User Manual

Page 90

Advertising
background image

90

Example: module #2 configured as a DUCKER, audio input IN6 and zones 1, 3, 13 and 15 enabled for priority broadcasting of IN6

signal when it exceeds the threshold, attenuating the existing audio content in the affected outputs

Knobs on the lower part of the section are used to adjust the way the DUCKER function performs:

THRESHOLD: activation threshold. When the module's input signal (INPUT selector) exceeds

this threshold, the DUCKER function is activated, sending the signal to the destination zones
and attenuating the other audio signals sent to the same zones (-80 to 0 dB)

DEPTH: attenuation applied on the rest of the signals sent to the destination zone(s) during

the time the DUCKER function is active (0 to 80 dB)

ATTACK: attack time. Determines the time the DUCKER takes to respond when the level

rises above the threshold (activating the attenuation of other signals in the destination zones).
The range covers from 5 ms to 2 s

HOLD: amount of time the DUCKER function remains active once the signal falls back below

the detection threshold. Adjustment range from 10 ms to 3 s

RELEASE: determines the time elapsed until attenuation stops after the time fixed for HOLD.

In this case, the range covers from 50 ms to 3 s.




Advertising