Alarm count, Group verifi cation type, Management of duress fingerprint – FingerTec R2 Manual User Manual

Page 29: Help key, Trigger methods, Alarm delay

Advertising
background image

29

NOTE

Do not using the same method and the same fingerprint during normal working days to avoid
triggering the alarm system and disrupting working environment.

CONTENTS

MANAGEMENT OF DURESS FINGERPRINT

Press Menu > Options > Access Options > Duress Options > Duress FP >. You can per-
form four tasks in this operation.

DURESS FP

WHAT IS IT FOR

New Enrollment

To perform a new fingerprint enrollment for duress purpose

Define Duress FP

To define the already enrolled fingerprint for duress purpose

Undefine Duress FP

To undefined selected enrolled duress fingerprint from the

terminal

Undefine All Duress FP

To undefined all enrolled duress fingerprints from the termina

l

HELP KEY

You can configure a Help Key in your terminal to function during duress situations. First,
you have to enable the Help Key by: Press Menu > Options > Access Options > Duress
Options > Help Key > Y. Then, press and hold the down arrow for 3s followed by the
duress fingerprint verification, to trigger alarm.

TRIGGER METHODS

The terminals offer 3 types of alarm trigger method. Press Menu > Options > Access Op-
tions > Duress Options > Choose your method > Y. You can choose one method only.

ALARM TRIGGER METHOD WHAT DOES IT MEAN?

1:1 Trigger

Triggering alarm using 1:1 method

1:N Trigger

Triggering alarm using 1:N method

Password Trigger

Triggering alarm using password method

ALARM DELAY

Set the timer to set off the alarm after successful duress finger verification. The time
range is from 0 to 254s. The type of output for alarm is NO/NC. Press Menu > Options >
Access Options > Duress Options > Alarm Delay > Set your value > OK

Alarm Count

There is a limit to unsuccessful verification by a user. Predefine the value of unsucessfull
verifications sofuat if a user exceeds the allowed times, the alarm will be triggered if
your terminal is installed with an alarm system. Press Menu > Options > Access Options
> Alarm CNT > Define the value > OK

Group Verifi cation Type

This function offers various verification type(s) for every group that can be set accord-
ing to time. Description of verification types available in FingerTec fingerprint terminal
is explained in Chapter 4: User. Press Menu > Options > Access Options > Group Ver-
Type > Select the Group > OK > Select the time > Down arrow and select Verification
Type. After finished, press OK.

Advertising
This manual is related to the following products: