Installation and setup of tcms v2, Connecting the terminals to tcms v2, Using usb to download/upload data – FingerTec TA200 Plus Manual User Manual

Page 18: Communication key

Advertising
background image

19

CONTENTS

Installation and Setup of TCMS V2

Install TCMS V2 in a PC that fulifills the software’s minimum requirements. Refer to

user.

fingertec.com/user-promanual.htm

for the TCMS V2 user guide online. Setup Wizard will

require you to do online activation before a connection can be established between TCMS

V2 and the terminals.

Connecting The Terminals to TCMS V2

determININg termINAl NUmBer:

Identify the number of your terminals to dif-

ferentiate them between one another. TCMS V2 can connect up to 999 units of terminal.

Press Menu > Options > Comm Opt > Dev Num > Select the number.

USINg tCP/IP:

IP address is important, as it is a unique address of the terminal in LAN.

Without the IP address, locating the specific terminal is not possible.

To input the IP ad-

dress of the terminal: Press Menu > Options > Comm Opt > IP Addr > Key in IP address.

SettINg UP etherNet:

It is important to setup the Ethernet to connect the termi-

nals using TCP/IP connection. Setting up the Ethernet is done by enabling the Ethernet

function: Press Menu > Options > Comm Opt > Ethernet > Yes. Turn off the terminal after

you have set the Ethernet setting to Yes. Now, plug-in the network plug to the Ethernet

interface and turn the power on.

Determining the Netmask, Gateway and NetSpeed:

For TCP/IP connection, please configure

the netmask, gateway and netspeed for the terminal.

Press Menu > Options > Comm Opt > NetMask > Insert the numbers.

Press Menu > Options > Comm Opt > Gateway > Insert the numbers.

Press Menu > Options > Comm Opt > NetSpeed > Choose the speed of your Ethernet connec-

tion.

USINg rS232 CoNNeCtIoN:

For connection via RS22,baudrate is the determinant

of communication speed between the terminal and the software. The higher the baudrate,

the faster the speed is.

To turn on RS232 connection and set the baudrate: Press Menu

> Options > Comm Opt > RS22 > Change the RS22 connection to Y.

To change baudrate:

Press Menu > Options > Comm Opt > Baudrate > Change the Baudrate accordingly.

USINg rS485 CoNNeCtIoN

: For connection via RS485, baudrate is also the deter-

minant of communication speed between the terminal and the software but the speed

must be according to the speed of theconverter. Check your converter for the speed.

To

turn on RS485 connection and set the baudrate:

Press Menu > Options > Comm Opt > RS22 >

Change the RS485 connection to Y.

To change baudrate:

Press Menu > Options > Comm Opt

> Baudrate > Change the Baudrate accordingly.

Using USB to Download/Upload Data

A USB flash disk is useful in cases where the terminal is installed far from a PC or there is

a connection problem. To determine the type of USB flash disks compatible with the ter-

minal, please refer to this link at

fingertec.com/newsletter/HL_74.html

using USB. Press

Menu > PenDrive Mgmt > Choose the operation that you want to carry out via USB flash

disk.

Communication Key

Since the software is controlled by an activation code and a product key, set the COMM key

to zero. Press Menu > Options > Comm Opt > COMM Key > Set to 0.

Advertising
This manual is related to the following products: