Lock, Door sensor delay, Door sensor mode – FingerTec Kadex Manual User Manual

Page 24: Door sensor alarm, Turning off alarm

Advertising
background image

24

CONTENTS

To use the Access Combo, users from all the three time zones must be present for
verification and the time period of the three groups must be valid in order to gain
access. As shown in these time zones, 13:00 is the overlapping time where all of them
can gain access.

To configure Access Combo:

press Menu > Options > Access Options > Access Comb

> Select the combination you want for example Comb1 > OK > input the number, in
this case 123 to represent GRP TP1, GRP TP2, GRP TP3> OK

Lock

The opening period of the electromagnetic lock or door bolt can be controlled ac-
cording to your requirement or preference. The default value is 150 which translates
to 3 sec. 50 is equivalent to 1 second. Press Menu > Options > Access Options > Lock >
Determine the value of lock delay.

Door Sensor Delay

Door sensor delay can be configured to alert users if a door is not closing well after
a time period. A door sensor must be installed prior to activation of this option. The
default period is 10seconds and the maximum period is 999seconds. Press Menu > Op-
tions > Access Options >Dsen Delay > Determine the value of lock delay.

Door Sensor Mode

Door sensor mode is to configure the time to alert an internal buzzer if the door is not
closing properly. The standard of door locking system includes:

Normally Closed (NC):

An electrical contact that regularly allows electricity to flow

until it is signaled to open

Normally Open (NO).:

An electrical contact that rarely allows electricity to flow. To

use door sensor, select NC. Press Menu > Options > Access Options > Dsen Mode >
Determine the type correctly > OK

Door Sensor Alarm

Door Sensor Alarm can be configured to alert users by using the alarm system if a door
is not closing well after a time period. An alarm system must be installed first to use
this operation. Press Menu > Options > Access Options > Dsen Alarm > Determine the
period > OK

Turning Off Alarm

There are scenarios that require you to turn off your alarm system and this can be done
through the terminal. To do this you have to press and hold the security button at the
back of the reader followed by pressing Menu > Turn Off Alarm.If you didn’t press the
security button, the message “System Broken!!!” message will be displayed when you
press the Turn Off Alarm operation button.

Advertising