DETAILS OF WIRING

AdapTec Plus supports 2 types of installations, Convenient or Secure. You
can select between modes by applying different wiring arrangements during
installation. Under Convenient mode, AdapTec Plus will unlock doors imme-
diately after receiving responses from FingerTec devices. This feature is sup-
ported by all FingerTec models.

For installations using Secure mode, there will be a 1s time delay when un-
locking the door after verification at FingerTec devices. This delay is due to the
26-bit Wiegand transmission of encrypted password from device to AdapTec
Plus. This is an optional security feature provided by AdapTec Plus for users
who favor more security (slight delay) over convenience (no delays).

AdapTec Plus works with FingerTec terminals via an encrypted Wiegand
signal to control the door open-close mechanism. Please make sure you are
using the following FingerTec models that support the encrypted 26-bit Wi-
egand signal to work with the AdapTec Plus to setup a door lock system:

Step

1

Look for the power input port on the
FingerTec terminal. Normally the con-
nection ports on the terminals are
marked as PWR/+12V (red wire) and
GND (black wire).

Step

2

Convenient Installation: Look for the
door lock output port NO and GND
from the terminal.
Secure Installation: Look for the Wi-
egand output port, WDO (green), WD1
(white) and GND (black) from the ter-
minal.

Step

3

Connect the wires from the terminals
to AdapTec Plus.

Convenient Installation: See diagram 1, page 8
for details. Secure Installation: See diagram 2,
page 8 for details.

Step

4

Connect the wires from AdapTec Plus
to the door lock system.

(See diagram 1, page 8 for details). (Ignore this
if you only want to use the system for time at-
tendance purposes)

Step

5

Connect AdapTec Plus to a 12VDC re-
chargeable backup battery.

(See diagram 1, page 8 for details). (This is
optional. Ignore this if you do not need any
backup power).

Step

6

Connect AdapTec Plus to a power
source (12VDC 3A).