Wiring diagrams, Benefi ts of using adaptec plus with alarm siren – FingerTec AdapTec Plus (New Model) User Manual

Page 8

Advertising
background image

9

AdapTec Plus

Connection

Points

GND

12V

Siren Mute

Button

Tamper

Siren

EM

+12V

Siren

Exit

Data

Switch

Out

Lock

Out

OV

Mute

Switch

OV

D1

D0

ALM +

ALM ----

Alarm

Siren

+ ---

Remark:

Set Auto Alarm in terminal to N.

Menu > Options > Sys Opt > Adv Opt >
Auto Alarm > N.

WIRING DIAGRAMS

3

ALARM SIREN •

R2, Kadex, m-Kadex, H2i and Face ID3

CONNECTING ADAPTEC PLUS TO AN ALARM SIREN

For all FingerTec door access control models, there is
a security button behind the terminal. During normal
operation, the security button is compressed and once
the terminal is dismantled, the button will be released
and a

“System broken”

message will appear onscreen.

During the release of the button, the terminal will output an alarm signal.
However, no alarm sound will be emitted if the terminal is not equipped
with an external siren.

To use the siren feature, we recommend that you install an additional
alarm siren and connect it to the FingerTec terminals.

Benefi ts of Using AdapTec Plus with Alarm Siren

We recommend that you install a terminal along with AdapTec Plus if you
plan to use the alarm siren. In AdapTec Plus, an additional port is read-
ily built to receive the alarm signal from the FingerTec terminals. AdapTec
Plus has an output of 12VDC and it is suitable for use with an alarm siren
that has the same power input. You do not need to source an additional
12VDC power supply for this purpose. Furthermore, AdapTec Plus comes
with a

“Siren Mute”

button where you can press the button to deactivate

the alarm siren when required.