FT-15(D) Technical Manual, Rev. 1.02 August 2010

Page 18 of 52

6.2 Weighing with Preset Vehicle Weight

In this vehicle weighing procedure the vehicle will be weighed only once. To spare time the net weight will be
calculated by using the preset vehicle weight. At first the vehicle weight has to be saved to the preset vehicle
weight memory or it can be entered numerically.

Steps

Vehicle

Position

Description

There is no vehicle
on the weighbridge.
(Unloaded Scale)

If the indication is not 0 kg, press the
<Zero> key before loading the scale in the
instrument ready status.

[

0

kg ]

Vehicle is parked on
the scale and the
engine is stopped.

Load the scale.

[

28680 kg

]

Press the <Preset vehicle weighing> key to
start the weighing cycle.
Message will be displayed for 1 second.

[ P.Vehic ]

[ P. No XX ]

Press the <M> key to select the preset
vehicle weight from the memory or press
the <ID> key for a numeric entry. Press the
<Enter> key.

[

4650 kg

]

The weight in the memory will be displayed
for 1 second.

[ V. Id ]
[

584

]

Enter the vehicle ID numerically if this entry
is defined (refer to parameter [042 ]).


Press the <Enter> key.

[ Id1 ]
[

78

]

Press the <M> key to select from the ID
memory or press the <ID> key for a
numeric entry, if this entry is defined (refer
to parameter [043 ]).


Press the <Enter> key.

[ Id2 ]
[

22

]

Press the <M> key to select from the ID
memory or press the <ID> key for a
numeric entry, if this entry is defined (refer
to parameter [044 ]).


Press the <Enter> key.

[ Print ]
[

24030 kg

]

If the vehicle has finalized the weighing
process, press the <Enter> key to save and
print the preset vehicle weighing ticket.

[ Unload ]
[

24030 kg

]

Message appears until the scale gets
unloaded.

Vehicle is on the
scale + the
displayed weight is
stable.

[

0 kg

]

Vehicle leaves the
scale.

Unload the scale.

If the displayed weight is less than 20e or
the <F> key is pressed, FT-15 returns to
the instrument ready status.

Advertising