Flintec FT-15D User Manual
Page 32
FT-15(D) Technical Manual, Rev. 1.02 August 2010
Page 32 of 52
The pin configuration of the optional D-Sub 25-pin female connector is given below.
Parameter [012]
Pin no. for stainless steel housing
is set to
“0” or “1”
is set to “2”
Pin no.
for desk type housing
(D-Sub, 25-pin, female)
J10 connector
(Option 1)
JR1 / JR2 connector
(Option 2 or 3)
TxD1; Par. [01-]
2
8
15
RxD1; Par. [01-]
3
7
14
TxD2; Par. [02-]
RTS1; Par. [01-]
4
3
10
RxD2; Par. [02-]
CTS1; Par. [01-]
5
2
9
GND (RS 232C)
7
6-9
13
R-; Par. [02-]
8
Not used
R+; Par. [02-]
9
Not used
T+; Par. [02-]
10
Not used
+V; Par. [02-]
11
Not used
Termination (RS 485)
19
Not used
Termination (RS 485)
20
Not used
A; Par. [02-]
21
5
12
B; Par. [02-]
22
4
11
T-; Par. [02-]
24
Not used
+24V; 20 mA CL
25
Not used
Shield D25
body
1
1
The RS485 interface termination can be done by short circuiting pin no. 19 and 20 at the desk and panel type
enclosures or by jumper JP4 on the interface board within the stainless steel housing . These short circuits
terminate the line with an internal termination resistor of 100 Ω.
The 20mA CL ASCII output is disabled by default. The connections should be made as given in figure 9.1 for
enabling this output. (Enabled output is not available for 12 V DC instruments ).
25
11
10
24
9
8
FT-1x
Figure 11.1
20 mA CL ASCII interface connection