FT-15(D) Technical Manual, Rev. 1.02 August 2010

Page 41 of 52

12 T

RAFFIC

L

IGHT

C

ONTROL

If the instrument is equipped with the Digital I/O option (3 inputs / 3 outputs) the traffic light control is activated
automatically. FT-15(D) assumes an unloaded weighbridge if the weight is less than 20e.

Traffic light control outputs functions are described below:

Output-1 Output-2

Active

Passive Active Passive

Ready for start,
weight < 20e

Entrance green

Exit red

Vehicle on scale;
weight > 20e

Entrance red

Exit red

Weighing finalized;
weight > 20e

Entrance red

Exit green

Weighing finalized;
weight < 20e

Entrance green

Exit red


Input-1 may be used for zeroing and Input-2 may be used for printing in ready status.


The electrical connection of the inputs and outputs should be made as shown in Fig. 12.1.

Figure 12.1

Digital I/O ports connection diagram

Voltage Current

Digital input

20 to 28 V DC

Max. 30 mA

Digital output

20 to 28 V DC

Max. 300 mA (sum of all 3 outputs)


The power for the digital I/O has to be supplied from an external power supply module.

The pin layout of the parallel Input/Output connector is given below.

Pin no. for stainless steel housing

Definition

Pin no. for desk type

(DB-Sub, 25-pin, female)

J10 connector

(Option 1)

JR1 / JR2 (Option 2 or 3)

0 V

13

1

1

+24V

12 - 24 - 25

2

2

Output 1

1

7

8

Output 2

3

8

7

Output 3 (not used)

5

9

6

Input 1

11

3

10

Input 2

10

4

11

Input 3(not used)

9

5

12

Shield

Connector Body

Not used

Not used