5 accumulated report for preset vehicle weights, 6 reprint the weighing ticket – Flintec FT-15D User Manual

Page 22

Advertising
background image

FT-15(D) Technical Manual, Rev. 1.02 August 2010

Page 22 of 52

7.5 Accumulated Report for Preset Vehicle Weights

You can print an accumulated weighing data by the
<Report Σ PV> key.

After pressing the <Report Accu PV> key in the
instrument ready status, the [Accu] message
appears. The report starts after pressing the <Enter>
key. The report includes the first CN, the last CN and
the totals.
The [DEL N] message appears after the report.
Press the <Enter> key to exit without clearing the
accumulator.
To clear the accumulator, press the preset vehicle
weight key, change the message to [DEL Y] and
press the <Enter> key. The [SURE] message will be
displayed. Then press the <Enter> key and
accumulator will be cleared.

Press the <Reset> key to cancel the report.



The accumulator report will be created as shown
below.


REPORT PVehicle Accumulator

CN Start: 234 Date: 01.01.2009
CN End: 456 Date: 14.01.2009

PV Code Weighing Qtity Total kg
----------------------------------------------------------

01

09

94680

03

248

425430

88 3

38540

-----------------------------------------------------------------
TOTAL 260 558650

7.6 Reprint the Weighing Ticket

You can reprint the last weighing ticket in the
instrument ready status. This feature gives the
operator a benefit in case of lost tickets or for any
reason non-printed tickets.

After pressing the <CN> key, press the <Enter> key
in the instrument ready status to reprint the last
weighing ticket. If you enter a new CN before you
press the <Enter> key, the related weighing ticket
will be printed.

Press the <F> key to return to the instrument ready
status or wait for a while.


Instrument Ready Status

[ XXXXXX ]

Ticket number

[ Print ]

Report Message

Instrument Ready Status

[ Accu? ]

Message to start report

[ Print ]

Report Message

[ DEL N ]

Message to start clearing accumulator

[ DEL Y ]

Message to validate

clearing accumulator

[ SUrE ? ]

Accumulator is

not cleared.

Accumulator is

cleared.

Advertising