The parameter block [9--] contains certain functions for checking and testing.

[9--] Diagnostics

The operations about checking and testing the instrument can be made here.

[90-] Tests

[900 ] Key Pad test

In this step each key’s ASCII code will be shown on the display as you press the related key. By this way you can test
if all the keys are functioning or not. Pressing “

” key will take you to the next parameter.

[901 ] Serial Interface-1 test

The characters in the alphabet will sequentially be transferred from serial interface-1 by pressing the “Zero” key
repeatedly. Received numerical data is shown on display.

[904 ] mV Indication (for FT-15 only)

When pressing the <Enter> key the output voltage of the load cell will be shown on the display. This uncalibrated
value is only for test- and service purposes.

[905 ] DLC Internal Count (for FT-15D only)

When pressing the <Enter> key the message [905 1 ] is shown. The number of the load cell can be selected by up
and down keys and internal counts can be seen by pressing the <Enter> key.
Press the <F> key to quit this parameter.

[91-] Serial Numbers

[910]

Instrument Serial No.

[911]

Option 1 Serial No.

[912]

Option 2 Serial No.

[913]

Option 3 Serial No

When pressing the <Enter> key the serial number of the instrument or the option will be shown.

[97-] Calibration Coefficients

The parameters located in this section are the calibration parameters of the instrument. If these values have
been noted this can help when a calibration problem occurs. You can refresh the calibration by entering the
correct values. Press the <Trans> key after the message [SAvE t ] appears on the display.

[99-] Printing Parameter Values

[990] Print All Parameters

By pressing the <Print> key all parameters can be printed.

[991] Loading Default Parameters

When pressing the <Enter> key the [ Ld dEf ] message appears on the display. Press the <Trans> key for loading
the default values or press the <F> key to go to “9-“ sub block.