Error Check Calculating:

CSUM = 0 – (Slave_Add + Function + … + Last_data)
(STX and CSUM are neglected while calculating CSUM)

Tool for counting:

0 1 2 3 4 5 6 7 8 9 A B C D E F


Example:
@|01|10|0008|0001|02||0006|DE|<Cr>

To get the check sum (here FA) you have to sum following numbers first:
01+10+00+08+00+01+02+00+06 = 22

Now you have to subtracte 22 from 00:
00 - 22 = DE

(Calculation examples: 00 – 10 = F0 ; 00 – 11 = EF)

Command

Function

(Read /

Write)

Address

register

Quantity
Address

register

Quantity

Data

register

Data Definition

Display value

03 (R)

0000

0002

--

-----

Current display value; gross or net
Transfer the replied status data (hex, 4 digits) into
binary (up to 16 digits) and compare the binary
digits with the following table.
Digit Definition
D0

Busy

1 – System Busy

D1 Data

ok

1 – Data ok
0 – Error

D2

Motion

1 – Weight is not stable

D3 0

NA

D4 0

NA

D5 Output

1

D6 Output

2

D7 Output

3

1 – Output active

D8 Input

1

D9 Input

2

D10 Input

3

1 – Input active

D11 0

NA

D12 0

NA
0 No

Errors

1

ADC out of range

2

ADC over range

3

ADC under range

4 System

fault

Status 03

(R)

0002

0001

--

-----

D13
D14
D15

Error Code;
transfer
D13, D14,
D15
(binary) to
decimal and
compare to
code

5

FT is not in
weighing mode

0003

0002

--

----

Reserved

Gross Weight

03 (R)

0005

0002

--

----

Current gross weight

Status

03 (R)

0007

0001

--

----

Same as address 0002

---- None

Control 10

(W)

0008

0001

02

0001 Zero



Examples:

The commands will be used for an indicator which instrument address is set to 1.


Reading weight data:

@,01,03,00,00,00,02,FA<Cr>

Reading status data:

@,01,03,00,02,00,01,F9<Cr>

Reading Tare data:

@,01,03,00,03,00,02,F7<Cr>

Zeroing: @,01,10,00,08,00,01,02,00,01,E3,<Cr>