11.2.3 Continuous Output Mode

The format and the definition of the continuous data output is given below (see also overview in chapter 11.1).

Status

Indicated

Tare

STX

STA

STB

STC

D5 D4 D3 D2 D1 D0 D5 D4 D3 D2 D1 D0 CR CHK

The definition of the status bytes STA, STB and STC is given below.

Definition Table for Status Byte A

Bits 0, 1 and 2

Bits 3 and 4

Bit 5

Bit 6

Bit 7

0 1 2 Decimal

point 3 4 Increment

size

0 0 0 XXXXOO

1 0

X

1

1 0 0

XXXXXO

0 1

X

2

0 1 0

XXXXXX

1 1

X

5

1 1 0 XXXXX.X

0 0 1 XXXX.XX

1 0 1 XXX.XXX

0 1 1 XX.XXXX

1 1 1 X.XXXXX

Always 1

Always 1

X

Definition Table for Status Byte B

Bit 0

Gross = 0

Net=1

Bit 1

Weight positive = 0

Weight negative=1

Bit 2

Overload = 1

Bit 3

Stable = 0

Unstable =1

Bit 4

Always = 1

Bit 5

Always = 1

Bit 6

When energized = 0

Zeroed = 1

Bit 7

x

Definition Table for Status Byte C

Bit 0

Always 0

Bit 1

Always 0

Bit 2

Always 0

Bit 3

Always 0

Bit 4

Always 1

Bit 5

Always 1

Bit 6

Always 0

Bit 7

x

CR =

( D7,D6,D5,D4,D3,D2,D1,D0 ) = ( X, 0, 0, 0, 1, 1, 0, 1 )

CSUM =

0 – ( STX

 STATUS A  .....  CR )

11.2.4 PC Software Interface Mode

After receving the command ASCII Z the instrument will be zeroed.
The command ASCII P requests the current weight values as indicated below:

G: 35070kg T: 0kg N: 35070kg *ALB: 781*

Gross value

SP

Always “0”

SP

Net value

SP

Alibi number

LF CR

M
S
D

L

S
D

M
S
D

L

S
D

M
S
D

L

S
D

M
S
D

L

S
D

13 3 13 3 13 3 12 1

1


The command ASCII R requests the last record from the alibi memory. The response is:

11.2.5 Host Mode

The indicator can communicate with a PC in host mode. You can upload or download data to the indicator by
adjusting the related interface parameters within the FLINTEC IndFace software or using the command sets
described in Appendix 2. This mode is convenient for process control applications which need not only the
weight data, but also require some uploads / downloads and status control.

000234 01.01.09 08:12 1111 Customer A Sample A 33320 11100 22220In

Ticket S

P

Date S

P

Time S

P

Vehicle S

P

ID1
Header

S
P

ID2
Header

S
P

1.Weight S

P

2.Weight S

P

Net CR LF

6

1

8

1

5

1 7 1 16 1

16 1

8 1

9 1

9 1

1

Advertising