9. If GTCOTEST indicates that the digitizer is functioning properly, check your software

application setup and AccuSet code for accuracy. If you have any questions about
your results or need help running GTCOTEST, contact our Technical Support Team
at 1-866-746-3015.

Reducing Monitor Interference

If you are experiencing monitor interference with your tablet, you can reduce the
interference by changing the frequency your tool uses. Pointing tools with FCC ID numbers
support two frequencies: ECPPPP, ECPPP2, ECPPLTP, ECPPCURSOR4, ECPPCURSOR16 and
ESPPCURSORII. Transducers with FCC ID numbers other than those listed must have
frequencies changed at GTCO CalComp by Turning Technologies.

Changing the Frequency of the Cordless Cursor

1. Place the cursor on the tablet surface.
2. Press Buttons 1 and 2 simultaneously and hold for approximately three seconds.
3. The cursor turns itself off. You will know the cursor is off when the power light on

the tablet begins blinking.

4. The cursor turns on again at the new frequency. You will know the cursor is on

when the power light glows steadily.

To return to the default frequency, repeat the above process. When you replace the cursor
batteries, the cursor is automatically reset to the default frequency.

Changing the Frequency of the Cordless Pen

Press both side buttons and the tip simultaneously and hold for approximately three
seconds. To return to the default frequency, repeat the above process. When you replace
the pen batteries, the pen resets to the default frequency.

Tablet Checklist

Is the tablet power supply plugged into both a serial connector and live outlet?

Is the tablet power switch on?

Does the power light glow steadily when the transducer is inside the drawing area?
Does it blink when the transducer is outside the drawing area?

The power light will blink if the transducer has gone into sleep mode. Press any
button on the transducer to activate it. If the power light continues to blink and the
transducer is in the drawing area, change its battery.

Are all cable connections tight?